UNILAB College Power Unit

UNILAB College Power Unit

E8G85483

Product code: E8G85483

-
+

Power supply for use by students in advanced courses where an accurately monitored voltage or current may be required. The output voltage is selected by a rotary switch on the front of the unit, output is up to a maximum of 25V. It provides 0 - 25V ac or smoothed dc adjusted by the rotary control at a maximum current of 8A. The ac and dc outputs may be used simultaneously, provided the combined output does not exceed 8A.

The illuminated digital display has two associated membrane switches with LED indicators. User can choose to display current (I) or voltage (V), for either the ac or dc output of the unit.

The internal, quiet-running fan will hardly be noticed but it reduces the already low thermal stress in the unit still further, ensuring long life of the instrument. Triple protection is provided by a resettable electronic overload trip, thermal transformer trip and slow-blow fuse on the primary.

Overloads are indicated by the LED changing from green to red.

The mains cord is kept tidy, by means of the cable retainer on the back of the unit which allows the cable to be stowed away neatly with the use of winding hooks and a clip to secure the cable.

  • Output voltage continuously variable by rotary control up to 25V
  • Continuously rated output of 8A, ac or dc, dc is unsmoothed
  • LCD indication of voltage or current, ac or dc selectable by membrane switches
  • Sockets accept standard 4mm plugs and shrouded plugs
  • Snap up handle - safe to carry with one hand
  • Internal fan for cool-running
  • Fully protected secondary by high speed, resettable electronic trip
  • Slow-blow fuse protection for transformer primary
  • Additional thermal trip protection for transformer
  • This device is compliant to EN61010-2010 with certificates available on request

Dimensions:

  • Width: 175mm.
  • Depth: 190mm (including cable clips 206mm).
  • Height: 341mm.
  • Mass: 5.9kg.
  • Robust
  • Rotary Voltage Selection - with digital read-out
  • Maximum Current: 8A
  • Applications throughout GCSE and A-Level
  • The overload light will change from green to red if the attached circuit is overloaded.

Further Information

Age Recommended from
14 Years
Brand
Unilab
Fuse
2A time delay
Humidity (%RH)
10 - 90
Internal Fuse
50mA time delay
Maximum Voltage
25V
Offers
Buy More Save More
Output
ac and dc
0-25V
variable
smoothed
Output Control
Variable
Power Supply Type
Spacesaver College
Product Type
Power Supply Units
Ratings
230V ac 50Hz 363VA
Temperature range (°C)
10 - 40

Documents

-
+

Power supply for use by students in advanced courses where an accurately monitored voltage or current may be required. The output voltage is selected by a rotary switch on the front of the unit, output is up to a maximum of 25V. It provides 0 - 25V ac or smoothed dc adjusted by the rotary control at a maximum current of 8A. The ac and dc outputs may be used simultaneously, provided the combined output does not exceed 8A.

The illuminated digital display has two associated membrane switches with LED indicators. User can choose to display current (I) or voltage (V), for either the ac or dc output of the unit.

The internal, quiet-running fan will hardly be noticed but it reduces the already low thermal stress in the unit still further, ensuring long life of the instrument. Triple protection is provided by a resettable electronic overload trip, thermal transformer trip and slow-blow fuse on the primary.

Overloads are indicated by the LED changing from green to red.

The mains cord is kept tidy, by means of the cable retainer on the back of the unit which allows the cable to be stowed away neatly with the use of winding hooks and a clip to secure the cable.

  • Output voltage continuously variable by rotary control up to 25V
  • Continuously rated output of 8A, ac or dc, dc is unsmoothed
  • LCD indication of voltage or current, ac or dc selectable by membrane switches
  • Sockets accept standard 4mm plugs and shrouded plugs
  • Snap up handle - safe to carry with one hand
  • Internal fan for cool-running
  • Fully protected secondary by high speed, resettable electronic trip
  • Slow-blow fuse protection for transformer primary
  • Additional thermal trip protection for transformer
  • This device is compliant to EN61010-2010 with certificates available on request

Dimensions:

  • Width: 175mm.
  • Depth: 190mm (including cable clips 206mm).
  • Height: 341mm.
  • Mass: 5.9kg.
  • Robust
  • Rotary Voltage Selection - with digital read-out
  • Maximum Current: 8A
  • Applications throughout GCSE and A-Level
  • The overload light will change from green to red if the attached circuit is overloaded.

Further Information

Age Recommended from
14 Years
Brand
Unilab
Fuse
2A time delay
Humidity (%RH)
10 - 90
Internal Fuse
50mA time delay
Maximum Voltage
25V
Offers
Buy More Save More
Output
ac and dc
0-25V
variable
smoothed
Output Control
Variable
Power Supply Type
Spacesaver College
Product Type
Power Supply Units
Ratings
230V ac 50Hz 363VA
Temperature range (°C)
10 - 40

Documents

You May Also Like